APPLICATION DESCRIPTION:
Identify part size to control the oven door
opening for heat testing
apparatus. To conserve energy, a dual door system is
employed for
both the oven entry and oven exit. Each furnace door to open
only enough to accommodate the current part.
·
Previous method opened the doors
completely, resulting in rapid cooling of the interior
chamber
APPLICATION REQUIREMENTS:
·
Doors open only enough to
accommodate current part
·
Measurement of height and width
of each part
·
Max force required to move
parts: 75lbs.
·
Pneumatic system
·
Energy conservation
TOL-O-MATIC SOLUTION:
·
(2) BC315 with APF option
The BC315 band cylinders move
the part to align with the door and measure part height and
width. The APF sends the measurement signal to the PLC which
coordinates the opening size to the oven entry doors. The
same door opening is signalled to the exit doors on
completion of heating cycle. This unique combination of
pneumatic rodless cylinder and position feedback allows
faster cycle times as well as energy savings.
|